6: Line and Tunnel Settings
XPort AR User Guide 39
1. Click Tunnel > Tunnel 1 > Serial Settings. Figure 6-5 shows the page that displays.
Figure 6-5 Tunnel 1 Serial Settings Web Page
2. View or modify the fields in Table 6-3.
Table 6-3 Tunnel 1 Serial Settings Fields
Fields Description
Line Settings Display only field. Current serial settings for the line.
Protocol Display only field. The protocol being used for the tunnel.
Buffer Size Enter the buffer size used for the tunneling of serial data received. Requires
reboot to take effect.
DTR Select when to assert DTR.
Unasserted
Asserted while connected—Asserted whenever a connect or an
accept mode tunnel connection is active.
Continuously asserted—Asserted regardless of the status of a tunnel
connection. Status of a tunnel connection does not affect the DTR
signal.