8: Line and Tunnel Settings
EDS1100/2100 User Guide 58
3. Click Submit.
Multiple Hosts
When you configure two or more hosts in the Tunnel web page, Host Mode displays as shown in
Figure 8-18.
Reconnect Timer Enter the reconnect time in milliseconds. The EDS1100/2100 attempts to
reconnect after the specified amount of time when a connection fails or when
exiting an established connection. This behavior depends upon the
Disconnect Mode.
Notes:
When you configure Tunnel - Connect Mode, you can specify a
number of milliseconds to attempt to reconnect after a dropped
connection has occurred. The default is 1500 milliseconds.
The Reconnect Timer only applies if a Disconnect Mode is configured.
With a Disconnect Mode set, the device server maintains a connection
until the disconnect mode condition is met (at which time the device
server closes the connection). If the tunnel is dropped due to conditions
beyond the device server, the device server attempts to re-establish a
failed connection when the specified reconnect interval reaches its limit.
Any network-side disconnect is considered an error and a reconnect is
attempted without regard to the Connect Mode settings. Simultaneous
Connect Mode connections require some Disconnect Mode
configurations or the connections will never terminate. See Disconnect
Mode on page 61
for more information about the parameters.
If Disconnect Mode is disabled and the network connection is dropped,
then the re-establishment of a tunnel connection is governed by the
configured Connect Mode settings.
Flush Serial Data Select whether to flush the serial line when a connection is made. Choices
are:
Enabled—Flush the serial line when a connection is made.
Disabled—Do not flush the serial line. This is the default.
Block Serial Data Select On to block (not tunnel) serial data transmitted to the EDS1100/2100.
Block Network Data Select On to block (not tunnel) network data transmitted to the EDS1100/
2100.
Email on Connect Select whether the EDS1100/2100 sends an email when a connection is
made. Select None if you do not want to send an email. Otherwise, select the
Email profile to use.
Email on Disconnect Select whether the EDS1100/2100 sends an email when a connection is
closed. Select None if you do not want to send an email. Otherwise, select
the Email profile to use.
CP Output Identifies a CP or CP Group whose value should change when a connection
is established and when it is dropped.
Table 8-17 Tunnel Connect Mode Fields (continued)
Field Description
Komentáře k této Příručce